Fetal heart rate monitor tutorial | |
Smart Bluetooth APP multinational language support |
|
Chinese language, English, Espana, Deutsch, Franc ais, اﻟﻌﺮﺑﯿﺔ, Русскии, Italiano | |
|
|
Android mobile phone: the mobile phone comes with a browser to open the link to install Play using video(Chinese) |
|
Apple iPhone: App store Search Angelbeats! https:// apps . apple . com/ us/ app/ angelbeats/ id 6737406479 |
|
Wechat user: [Bwmay] wechat small program | |
Welcome to use the tire, the following small experience can make you more skilled use of instruments, as soon as possible to hear the baby strong tire sound. The first First, it takes good patience. The baby is very small, and the environment in the stomach is very complex. It takes a lot of attempts to find the position of the fetal heart. Especially in the first trimester, when inexperienced, it is difficult to find before 12 weeks. Pregnant mothers can use the instrument to detect their heart rate to familiarize themselves with the instrument. |
|
The most important thing is to find the correct fetal sound when measuring it | |
Based on the working principle of the product, the value of the correct fetal heart sound is found, and you should not be disturbed by the value during the use. Please note that the first element of the use of tire is the voice, the voice is not the value will lose meaning. Listen first, listen to the sound, hear the sound of the fetal heart, in the judgment of whether the value is in the normal range, the sound is clear has the correct value. The general normal fetal heart rate value is between 120 and 160. A value of around 100 bmp may be Bao Mas own heart rate, arterial or umbilical cord sound. Play the reference sound |
|
Early pregnancy monitoring confusion |
|
Generally speaking, nine weeks of measurement, is 9 weeks of time is basically can hear the sound.11,12 weeks. But this is related to the measurement method and proficiency, you can generally measure your heart rate, experience the feeling of the measurement, feel the Angle and strength, and the coupling | |
Effect of the combination agent. In the early pregnancy, the signal of fetal heart is not as large as that of arterial umbilical cord. At this stage, the fetus develops rapidly. Generally, it is easy to find clear fetal sound at 14 or 15 weeks. | |
Why is the noise so loud? Find the right fetal heart is good to? |
|
The instrument adopts the advanced audio automatic gain function. When the exact position of the fetal heart is not found in the early pregnancy, the system enlarges the ambient sound so that the user can find the position of the fetal heart. When the user finds the fetal heart, the noise will automatically disappear. Its like there is white noise without the radio, when you find the channel with a signal, the noise will disappear. The coupling agent should be applied evenly and gently on the skin to moisten the skin and play the role of lubrication and air elimination. Excessive coupling agent on the probe may form a reflective sphere, causing noise. |
|
Fetal movement count operation | |
I 100 series split machine manual tire movement is long press the handle, that button will show FM, and then feel the tire movement press once, Manual fetal movement is more accurate. There is a timing in the lower left corner of the screen. Bluetooth connection can be intelligent number of fetal movement, but Bluetooth needs to use this instrument very skillfully. Moving the probe produces a noise that affects the accuracy of the log fetal movement. But the movement doesnt have to be very accurate, just a few times an hour. It is mainly used to monitor whether the fetus is deficient in hypoxia. Because of the fetal movement parameters, it does not have a clear quantitative standard, the inspection doctor generally said that 5 minutes, 10 minutes once, several times an hour can be. Fetal movement can be timely detection of fetal hypoxia. If no fetal movement is found in the late pregnancy, it is necessary to go to the hospital for examination |
|
Play several movement video | |
The i200 series all-in-one machine presses the OK button and the volume button at the same time to enter the fetal movement counting mode. The screen displays F00 and presses the OK button fetal movement number + 1. When the Bluetooth APP is connected, the APP records the fetal movement times and measurement time. | |
Bao Ma is easy to ignore the first points | |
Pay attention to these points, looking for the fetal heart will be a little more convenient: 1, need to lie flat, do not sit, abdomen stretch.2. The fetal heart position may be a little lower than you think. Pay attention to check the fetal heart heart reference location map。 3, need to press the probe. Signal loss is large when there is air between the sensor and the skin.4, with the method of point probe measurement. The probe is a highly sensitive component, and the probe slide generates more noise, which affects the accuracy of the desired data.5. Use an appropriate amount of the coupling agent. The coupling agent acts to lubrication and eliminate air. Increasing force pressing can squeeze out the excess couplings.6, at the same time, long press the volume + -button, you can switch the voice mode, the fetal heart rate in Between 120 and 160, the instrument will indicate a normal fetal heart rate. |
|
The point exploration technique reduces the noise | |
Use the dot probe method, do not move the probe frequently, move toward where the sound is clear, move a point to stay for a while. Deing point by point where the sound is clear. The instrument probe is highly sensitive, sliding will also produce noise, affect the judgment. | |
play video | |
Wechat small program Bluetooth link description | |
Use wechat to first turn on the mobile phone Bluetooth function, and then turn on the machine, In the case of the machine boot, scan the following QR code for the first time to open the small program, the second pair. There is a pop-up request Bluetooth connection must choose allowed, is generally used to refuse, resulting in the connection can not this time delete the small program, download, select allow that is approve. Keep the system updated, mobile phone and small program system updated, it is best to restart. Some machines do not restart the cache for a long time. The product uses the broadcast protocol, do not have to pair in the pairing list, if the pair is cancelled first. If wechat double open, change a number to try. If you do not open the location, open the location service and try again. The applet needs to call the location information of the system. Measure at the measurement page point, if the Bluetooth is not connected, return to the measurement page repeatedly several times. Please ignore the ads pushed by the platform. Welcome to download the independent APP is more convenient operation, more rich functions. Save the following QR code to collect the mobile phone can be used at any time. |
|
![]() |
|
Play a Bluetooth connection video | |
Introduction Video Links |
|
Boot it up to the simple use of the video. |
|
Introduction operation instructions. | |
1. Play the use of the tutorial: the following separate (the tutorial is only to teach you how to based the use, find fetal heart, other use details please see notes and instructions) play the video 2. Before using it, recall the place of the fetal heart when you were in the hospital, which is the most accurate position of the fetal heart.[Frequency of use] The baby is normal 1-2 times a day to listen to the fetal heart sound, 3-5 minutes each time, if the baby abnormal needs to extend the monitoring time, pregnant mother feel their chest tightness also need real-time monitoring, found fetal heart abnormalities need to go to the hospital in time ~ [recommended monitoring time]. The expectant mother gets up 30 times in the morning | |
Within minutes (appropriate holding urine in early pregnancy) can change the distance between the fetus and the probe, and the fetal heart is more easily monitored in the focal position; within 30-60 minutes after lunch; 30 minutes before bedtime, these times will be measured more accurately. |
|
Voice broadcast switch | |
At the same time, long press the volume plus and subtract button to switch the voice broadcast function. |
|
Instructions for using the charging instrument | |
The charging tire has a built-in battery that can be charged. User does not need to replace the battery. Low battery power affects the sound clarity, please charge in time. Charge with the power adapter of the mobile phone and the charging cable of the USB TypeC interface.(Apple pd protocol power adapter is not supported) | |
![]() |
|
Instructions for battery model use | |
The battery uses No. 5 alkaline battery 2 (AAx 2), shows the low power, noise, please replace the battery in time. | |
![]() |
|
A Schematic diagram of the fetal heart rate position | |
![]() |
|
Fetal heart location video |
|
In the early pregnancy, the fetal signal is small, and the fetal heart position is very important. The probe is aimed at the fetus to hear the correct fetal sound. Fetal heart Position is variable, and multiple locations need to be detected by point probe. In order to find the exact position, to get a clear fetal sound. |
|
Position is variable, and multiple locations need to be detected by point probe. In order to find the exact position, to get a clear fetal sound. |
|
14 weeks of reference video |
|
Play the fetal heart sound reference video Because the fetal position is different, the operation Angle of the instrument is different, the sound quality of the fetal sound is normal, the fetal heart rate rhythm is correct. General fetal heart rate than the adult heart rate rhythm |
|
Regarding the coupling agent |
|
Please use a superconducting level ultrasonic coupling agent to effectively reduce the noise. Use body wash, essential oil, or even clean water take the place of. It is mainly to exclude the space between the probe and the skin, increase the lubrication, and reduce the role of noise. In cold weather, the coupling agent package can be soaked in warm water to reduce the irritation of the skin with the cold coupling agent and increase the comfort. |
|
I wish the mothers a happy pregnancy, peace and joy!!! | |
|
|
Copyright © 2014-2024 BWMAY Healthy . | |
|